Advantage Chair and Stand. Advantage Plus Chair and Stand. Advantage Tilt Chair. AP Auto Projector. AR Auto Refractor. ClearChart 1 Digital Acuity System. Corneal Topography System. CT Contact Tonometer.
Custom II Chair and Stand. IOPac Advanced. IOPac Standard. LensChek Lensometer. Measure There are several options available at this point: The Forehead Rest may be slid to the opposite side to continue taking measurements on the other eye All data may be cleared and other measurements taken Clear Data Page Low Confidence Readings Continued Low Confidence Readings During the measurement process, the AT may detect a condition that could create a low confidence reading, which is identified with an asterisk after the reading.
Since this measurement cycle is so short, IOP readings can be acquired at different times within a cardiac pulse period. Therefore, repetitive readings for an eye may fluctuate from 2 to 4 mmHg during this cardiac period. After three attempts, the instrument will back away completely, and the screen will change to that shown below.
Should this situation arise, make sure the patient is not touching the AT anywhere near its nosepiece. The instrument will not function until the finger is removed. This will clear all data from the memory and the screen. The instrument is now ready for the next patient. Replace fuses with only a rating of T1. An internal fuse for the power circuits is located on the main circuit board inside the unit. Note: Replacement of this fuse must be performed by qualified service personnel only.
Page Printer Paper Maintenance Continued Printer Paper Instructions for changing printer paper can be found on the inside of the printer door.
To order replacement thermal paper, call your local dealer and ask for replacement paper, catalog No. These screens are intended to be used as a quick reference to a selection of operations.
The screen will change and look similar to that below. Printer not printing. Printer out of paper. Printer paper in backwards. Reverse the printer paper. For automated practices, data can be sent directly to a practice database through an RS interface. The AT is maintenance-free and has no bulbs to change. Superior Technology Means Accuracy and Reliability More than 27 years of clinical experience has been combined with the latest microprocessor control technology to bring you the most advanced NCT available.
Numerous clinical studies have shown that Reichert NCTs provide readings which consistently correlate with expertly executed Goldmann measurements. The AT eliminates operator variance by utilizing microprocessor control technology and objective measurement criteria. IOP measurement was never easier, quicker or more accurate. Click to enlarge.
Reichert AT AutoTonometer.